EPA 608 Type 2 Practice Test 2025 (High Pressure Appliances)

Last Updated on April 21, 2025

EPA 608 Type 2 Practice Test 2025 (High or Very High-Pressure Appliances) Questions and Answers. You can free prepare for the EPA 608 Certification Exam on our website.

High-pressure or extremely high-pressure systems are covered in the Type II exam, but not vehicle air conditioning or small appliances. Although the recovery procedures and standards are also part of this exam, the focus is more on leak detection.

In the actual test, there will be 25 questions with the following subject matter:

  1. Before charging a system, it is essential to know the correct methods for identifying leaks and conducting a leak test.
  2. Annual leak rate for systems holding more than 50 pounds of refrigerant in commercial and industrial refrigeration
  3. Techniques and needs for recovery
  4. The best way to manage emissions while the system is being recovered and reduce cross-contamination
  5. Recovery requirements for the disposal, maintenance, and leaks of these systems.
  6. The determination of a high-pressure system’s essential parts
  7. How to do the pressure/temperature test and where the refrigerant is situated in the system

EPA 608 Type 2 Practice Test (High or Very High Pressure Appliances)

0%
101

EPA 608 Type 2 High or Very high Pressure Appliances

1 / 40

1) What are the typical pressure settings for rupture discs on low pressure systems and recovery equipment?

2 / 40

2) What is the primary purpose of a condenser in a refrigeration system?

3 / 40

3) When using a system-dependent recovery system with an operating compressor, where should the refrigerant be recovered from?

4 / 40

4) What type of refrigerant was the most common before outlawing CFCs and HCFCs?

5 / 40

5) What is the purpose of the filter drier and when should it be changed?

6 / 40

6) Before charging a new system with refrigerant, what should be done?

7 / 40

7) What is the primary purpose of a filter-drier in a refrigeration system?

8 / 40

8) Which refrigerant can be used for leak detection as a trace gas and pressurized with nitrogen?

9 / 40

9) What type of oil is commonly used with R-22 refrigerant?

10 / 40

10) Why is it important to regularly check and repair refrigerant leaks?

11 / 40

11) Industrial process and commercial refrigeration equipment with over 50 pounds of refrigerant with an annual leak rate of ___ % requires repair under EPA regulations.

12 / 40

12) When using a system-dependent recovery system with a non-operating compressor, where should the refrigerant be recovered from?

13 / 40

13) Using large vacuum pumps can lead to freezing of water in the system. What are ways the technician can help prevent the freezing?

14 / 40

14) What tools can you use to find the general area of leaks and pinpoint leaks?

15 / 40

15) Industrial process and commercial refrigeration equipment with over 50 pounds of refrigerant with an annual leak rate of ___ % requires repair under EPA regulations.

16 / 40

16) Using large vacuum pumps can lead to freezing of water in the system. What are ways the technician can help prevent the freezing?

17 / 40

17) What is the primary purpose of a condenser in a refrigeration system?

18 / 40

18) How can you tell through a sight glass if there is excess moisture in the system?

19 / 40

19) The required level of evacuation for recovery equipment manufactured after November 15, 1993, on a system containing less than 200 pounds of R-12 refrigerant is:

20 / 40

20) How can you increase the pressure in the system to leak check a low-pressure system?

21 / 40

21) Comfort cooling chillers and all other equipment with over 50 pounds of refrigerant with an annual leak rate of ___ % requires repair under EPA regulations:

22 / 40

22) What must be done before opening a refrigeration system for maintenance?

23 / 40

23) What is the most effective way to remove trapped refrigerant from oil during recovery?

24 / 40

24) Comfort cooling chillers and all other equipment with over 50 pounds of refrigerant with an annual leak rate of ___ % requires repair under EPA regulations:

25 / 40

25) What type of refrigerant was the most common before outlawing CFCs and HCFCs?

26 / 40

26) Why should refrigerant cylinders not be filled more than 80%?

27 / 40

27) Traces of oil around a sight glass inlet fitting of a refrigeration system might be the indication of:

28 / 40

28) What is the primary function of an evaporator in a refrigeration system?

29 / 40

29) Describe ways you can visually look for leaks.

30 / 40

30) How should a water box be leak tested?

31 / 40

31) Type II classification, as identified by EPA, applies to what equipment?

32 / 40

32) What should be done with leaks in small appliances?

33 / 40

33) How can you tell what type of refrigerant is in a system?

34 / 40

34) What are the leak repair requirements for comfort cooling appliances and commercial appliances containing 50 lbs. or more of refrigerant?

35 / 40

35) The required level of evacuation for recovery equipment manufactured after November 15, 1993, on a system containing less than 200 pounds of R-12 refrigerant is:

36 / 40

36) What should be done if a refrigerant cylinder shows signs of rust or damage?

37 / 40

37) What safety precaution should be taken when working with refrigerants?

38 / 40

38) How can you tell through a sight glass if there is excess moisture in the system?

39 / 40

39) What safety device is used to prevent over-pressurization in a refrigeration system?

40 / 40

40) What is the purpose of the filter drier and when should it be changed?