EPA 608 Type 3 Practice Test 2025 (Low-pressure Appliances)

Last Updated on January 18, 2025

EPA 608 Type 3 Practice Test 2025 (Low-pressure Appliances) certification exam questions answers. You can prepare for the EPA 608 Section Type III Certification Exam on our website for free.

The Type III EPA certification will encompass low-pressure appliance maintenance or disposal, leak detection, leak repair specifications, recovery procedures, and refrigeration. Although these requirements may be similar to Type II, low-pressure systems are designed very differently. Learning with this interactive Type III exam preparation course will teach you more about these variations (and the following subjects).

You’ll also need to be familiar with the following for the exam:

  1. Evidence of leaks
  2. Centrifugal chillers’ max leak test pressure
  3. What to look for and how to fix leaks in these systems
  4. Evacuation necessities
  5. Understanding the definition of a “major repair”
  6. ASRAE Standard 15 specifications

EPA 608 Type 3 Practice Test (Low-pressure Appliances)

0%
35

EPA 608 Type 3 Low-pressure Appliances

1 / 40

1) What equipment should be used to test a tube?

2 / 40

2) How can you speed up the vapor recovery process?

3 / 40

3) What can happen if you heat a refrigerant cylinder?

4 / 40

4) After removal of liquid, about how much vapor will remain in the system on a 350 ton R-11 chiller?

5 / 40

5) What can happen if you heat a refrigerant cylinder?

6 / 40

6) After removal of liquid, about how much vapor will remain in the system on a 350 ton R-11 chiller?

7 / 40

7) What must be done before opening or removing any parts of a low-pressure system?

8 / 40

8) What are the leak repair requirements for comfort cooling appliances and commercial appliances containing 50 lbs. or more of refrigerant?

9 / 40

9) Where does the water typically come from in a water cooled condensing system?

10 / 40

10) What needs to be done to leak check a low pressure system?

11 / 40

11) Why should oxygen or compressed air never be used to pressurize a system?

12 / 40

12) Does refrigerant go out of the system in low pressure systems or does air and moisture go in?

13 / 40

13) What is the required evacuation level for a low-pressure appliance before disposing of it?

14 / 40

14) What are the leak repair requirements for comfort cooling appliances and commercial appliances containing 50 lbs. or more of refrigerant?

15 / 40

15) What should be done to prevent freezing during the evacuation of a low-pressure chiller?

16 / 40

16) How should a water box be leak tested?

17 / 40

17) What safety measure should be taken when working with low-pressure refrigerants?

18 / 40

18) What are the typical pressure settings for rupture discs on low pressure systems and recovery equipment?

19 / 40

19) What is the primary purpose of a purge unit on a low-pressure chiller?

20 / 40

20) How should a technician recover refrigerant from a system using R-11 or R-123?

21 / 40

21) What is a hydrostatic tube test kit used for?

22 / 40

22) What should be done if a rupture disc fails during pressurization?

23 / 40

23) How should a technician recover refrigerant from a system using R-11 or R-123?

24 / 40

24) In a system using a water cooled condenser, what components should be kept on?

25 / 40

25) What must be done before opening or removing any parts of a low-pressure system?

26 / 40

26) What are the typical pressure settings for rupture discs on low pressure systems and recovery equipment?

27 / 40

27) What can happen if you exceed 10 psig while pressurizing the system?

28 / 40

28) What should be done to prevent freezing during the evacuation of a low-pressure chiller?

29 / 40

29) What type of gauge is used to measure the vacuum level in a low-pressure system?

30 / 40

30) In a system using a water cooled condenser, what components should be kept on?

31 / 40

31) What is a hydrostatic tube test kit used for?

32 / 40

32) How can you speed up the vapor recovery process?

33 / 40

33) Where does the water typically come from in a water cooled condensing system?

34 / 40

34) What equipment should be used to test a tube?

35 / 40

35) Where do leaks commonly occur in low pressure systems?

36 / 40

36) Where do leaks commonly occur in open-drive type compressor systems?

37 / 40

37) How often should a low-pressure chiller be leak tested according to ASHRAE guidelines?

38 / 40

38) When should a low pressure system be leak checked according to ASHRAE guideline 3-1996?

39 / 40

39) Why should oxygen or compressed air never be used to pressurize a system?

40 / 40

40) How should a water box be leak tested?